Low voltage equipment

CYB7LE-100 Type multifunctional protection leakage circuit breaker

  • Product ID:Low voltage equipment
  • Whatsapp & Wechat:+8613868719385
  • Phone: +8613868719385
  • Tel: +86 577 27880251
  • E-mail: info@cyawit.com
  • FEEDBACK

CYB7LE-100 arth leakage circuit breaker (hereinafter referred to as RCB0) is suitable for circuits with AC 50Hz, rated voltage of 230V-400V and rated current of 100A. When personal electric shock or power grid leakage,overvoltage and undervoltage reach the set value, the earth leakage circuit breaker can quickly cut off the power supply in a very short time. When the monitoring temperature of the earth leakage circuit breaker reaches the setvalue, the product will give an alarm sound to protect people and use. It has the functions of overload, short circuit, leakage, overvoltage, undervoltage and overtemperature protection, and can also make and break electrical devices and lighting lines infrequently under normal conditions, especially
suitable for industrial and commercial lighting distribution systems. The product is small in size, compact in structure, better in cost performance than other similar products, beautiful in appearance and high
in breaking capacity, and is a good choice for household power distribution. This product conforms to GB/T 16917.1 and IEC 61009-1 standards.

2. Normal working conditions
2.1 ambient air temperature
The ambient air temperature is not lower than -5°C, not higher than +40°C, and the daily average is not higher than +35°C.
2.2 elevation: the elevation of the installation site shall not exceed2000m.

2.3 Atmospheric conditions
The air is clean, and the relative humidity of the air does not exceed 50% when the maximum temperature is +40°C. Higher relative humidity can be allowed at lower temperature, for example, at +20°C. the relative humidity does not exceed 90%. Appropriate measures should be taken for the occasional moderate condensation due to temperature changes.
2.4 Installation category
The installation categories are Il and Ill.

2.5 Pollution level
The pollution level is Grade 2.
2.6 Installation type
Standard guide rails are adopted for installation, and the specifications of the guide rails meet the appendix of GB/T19334-2003. AA.1 TH35~7.5 installation guide rail requirements.
2.7 Installation conditions:

The external magnetic field where the installation factory is located should not exceed 5 times of the geomagnetic field in any direction, and RCB0 should generally be installed vertically, with the handle upward as the power-on position. There should be no obvious impact and vibration at the installation place, and no corrosive and explosive gas exists.
2.8 Connection mode
Wiring frame screw wire pressing type

Outline and installation dimensions

 